21
Model C300 NP Operating Procedures
SanitizingNote: If a unit is sanitized, and will not be used for
an extended period of time, clean water should be
used to flush all sanitizer from the lines. Remove t he
water from all the lines and components prior to
storage of the unit. Upon return to service, the unit
must be sanitized prior to use.
Step 1
Open the lighted display door. Place the control
switch in the ON position.
Figure 22
Step 2
Prepare two gallons (7.6 liters) of an approved 100
PPM sanitizing solution (example: Kay-5R). USE
WARM WATER AND FOLLOW THE
MANUFACTURER'S SPECIFICATIONS.
Important: Make sure the sanitizer is com pletely
dissolved.
Step 3
Using an empty bag of syrup, cut the syrup line
connector from the end of the bag.
Figure 23
Step 4
Connect the syrup line to the syrup line connector
that was cut from the syrup bag.
Figure 24
Step 5
With the bag connector attached to the syrup line,
place the syrup line into the pail of sanitizing
solution.
Figure 25
Step 6
To place the left freezing cylinder in the SANITI ZE
mode, press the MENU (SEL) key. Move the cur sor
by pressing the AUTO (- ->) key until the t hird line
indicatesRINSE / SANITIZE.
OPERATOR MENU
ABCDEFGHI
RINSE / SANITIZE
<- - --> SEL