14 Model C300 NPImportant: Tothe Operator
The fourth feature will display the Power Saver
Mode, OFF, REST, or STANDBY status.
If the Power Saver Mode is OFF, the f ollowing
screen will be displayed.
POWER SAVER MODE
OFF
SEL
If a Power Saver Mode is programmed, one of the
following screens will appear.
POWER SAVER REST
CYCLE 1 SUN 01:00
SUN 08:30
+++ --- SEL
POWER SAVER STANDBY
CYCLE 1 SUN 01:00
SUN 08:30
+++ --- SEL
The fifth feature will indicate the left side def rost time
and which day(s) the defrost will occur.
DEFROST TIME LEFT
CYCLE 1 ALL 09:00
+++ --- SEL
DEFROST TIME LEFT
CYCLE 1 SUN 09:00
<-- --> +++ --- SEL
The sixth feature will indicate the right side defrost
time and which day(s) the defrost will occur.
DEFROST TIME RIGHT
CYCLE 1 ALL 10:00
+++ --- SEL
DEFROST TIME RIGHT
CYCLE 1 SUN 10:00
<-- --> +++ --- SEL
Press the MENU(SEL) key to return to the
OPERATOR MENU.
Screen F is CURRENT CONDITIONS. This screen
displays the current viscosity, product temperature,
and pressure for each freezing cylinder. An asterisk
will indicate which side is refrigerating. Press the
MENU (SEL) keyto return to the OPERATOR
MENU.
Note: Viscosity is checked only when product
temperature is below 40_F/4.4_C.
CURRENT CONDITIONS
L*1200Hd 27.3F
R*1200Hd 27.3F SEL
Screen G is FAULT HISTORY. This option
provides a record of the last 20 faults. The display
also indicates the date and time each fault occurs.
FAULT HISTORY 1
10/25/06 08:34
NO FAULT FOUND
<-- -->+++ --- SEL
Press the AUTO (- ->) and OFF (<- -) keys t o
increase or decrease the fault page.
Page numbers are located in the upper right hand
corner of the display. The most recently recorded
fault will appear on page 1. The fault descriptio n is
listed on the third line of the fault page.
FAULT HISTORY 2
10/25/06
R SYRUP PRESS LOW 08:33
<-- -->+++ --- SEL