2Model C300 NPTo the Installer
110506
Electrical Connections
Each unit requires one power supply for each data
label on the unit. Check the data label(s) on the
freezer for branch circuit overcurrent prot ection or
fuse, circuit ampacity, and other electrical
specifications. Refer to the wiring diagram provided
inside of the control box for proper power
connections.
In the United States, this equipment is intended t o
be installed in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70-1987. The
purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety.
Compliance therewith and proper maintenance will
result in an installation essentially free from hazard!
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
Stationary appliances which are not equipped with a
power cord and a plug or other device to disconnect
the appliance from the power source must have an
all-pole disconnecting device with a contact gap of at
least 3 mm installed in the external installation.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
Beater rotation must be clockwise as viewed looking
into the freezing cylinder.
Figure 2
The following procedures should be performed by a
trained service technician:
To correct rotation on a single-phase unit, change
the leads inside the beater motor. Follow the
diagram printed on the motor. (Note: Three-phase
units have single-phase motors.)