25
Model C302 O perating Procedures
Step 5
With the bag connector attached to the syrup line,
place the syrup line into the pail of sanitizing
solution.
Figure 28
Step 6
To place the left freezing cylinder in the SANITI ZE
mode, press the MENU (SEL) key. Move the cur sor
by pressing the AUTO (- ->) key until the t hird line
indicatesRINSE / SANITIZE.
OPERATOR MENU
ABCDEFGHI
RINSE / SANITIZE
<- - --> SEL
Step 7
Press the MENU (SEL) key. Move the cursor under
the word “SANITIZE” by pressing the O FF (<- -)key.
RINSE / SANITIZE
RINSE SANITIZE EXIT
-----
<- - --> SEL
Step 8
Pressing the MENU (SEL) key will give you the
option for sanitizing the left freezing cylinder. Move
the cursor under the word “YES”. Pressing the
MENU (SEL) key at this time will start the f low of
sanitizing solution into the left freezing cylinder.
SANITIZE
LEFT SIDE YES NO
---
<- - --> SEL
Step 9
Repeat Steps 6 - 8 for the right freezi ng cylinder.
Note: There is a left and a right freezing cylinder for
each LCD.
SANITIZE
RIGHT SIDE YES NO
---
<- - --> SEL
Step 10
Open the prime plugs. Place an empty pail under the
door spouts. When sanitizing solution fills the
freezing cylinders approximately 2/3 full, close t he
prime plugs.
Figure 29
Step 11
Continue filling the freezing cylinders with sanitizing
solution until the solution purges out of the relief
valve at the top of the mix tank, and begins draining
into the front drip tray. Press the O FF (<- -) key.