26 Model C302Operating Procedures
Step 12
Press the BEATER (- - -) key. Agitate the solution in
the freezing cylinders for five minutes.
Figure 30
Step 13
With a pail beneath the door spouts, open the draw
valves and drain all the solution from the freezing
cylinders. Press the OFF (<- -) key and close the
draw valves.
Figure 31
Step 14
Disconnect the syrup connectors in the sanitizing
solution.
Step 15
Repeat these steps for the other sid e of the
machine.
Priming/Brixing
Step 1
Connect the syrup line to the Bag-in-Box (BIB)
syrup.
Step 2
Remove the drip tray, splash shieldand the lower
front panel to gain access to the syrup sampling
valves.
Step 3
Open the prime plug.
Figure 32
Step 4
Place the sampling valve in the OFF (center)
position.
Figure 33