27
Model C302 O perating Procedures
Step 5
Press the PRIME (+ + +) key.
Figure 34
Step 6
Slowly move the syrup samplingvalve to the fully
open position by turning the handle “down” toward
the sampling line. Allow the liquid to run into a pail
until all the sanitizer is removed and full strength
product is flowing.
Figure 35
Brix is the ratio of syrup to water which will directly
affect the quality and taste of the product . Brixing
should be done before priming the freezer and when
a change in syrup flavor has been made.
Step 7
Pour the product from the syrup sampling valve into
a cup. Close the syrup sampling valve by turning the
handle to the center position.
Figure 36
Step 8
Stir the finished product. Pour a small amount of
product over the refractometer. The br ix reading
should register 13 to 14. A reading higher than this
would cause a darker, richer product. The
refrigeration system would have to run longer to
freeze this excess syrup. A reading lower than this
could cause a freeze-up in the freezing cylinder
because of the excess water.
Figure 37