Model C302 To the Installer
101130
Electrical ConnectionsEach freezer requires one power supply. Check the
data label on the freezer for branch circuit
overcurrent protection or fuse, circuit ampacity and
electrical specifications. Refer to the wiring diagr am
provided inside of the control box, for proper power
connections.
In the United States, this equipment is intended t o
be installed in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70-1987. In all
other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
The purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety.
Compliance therewith and proper maintenance will
result in an installation essentially free from hazard!
The NEC is a United States regulatory agency.
International users must follow local electrical codes .
FOLLOW YOUR LOCAL ELECTRICAL CODES!
CAUTION: THIS EQUIPMENT M UST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
This unit is provided with an equipotential
grounding lug that is to be properly attached to the
rear of the frame by the authorized installer. T he
installation location is marked by the equipotential
bonding symbol (5021 of IEC 60417-1) on both the
removable panel and the equipment's frame.
SStationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an all-pole
disconnecting device with a contact gap of
at least 3 mm installed in the external
installation.
SAppliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected or not used for long
periods, or during initial installation, shall
have protective devices such as a GFI, to
protect against the leakage of current,
installed by the authorized personnel to the
local codes.
SSupply cords used with this unit shall be
oil-resistant, sheathed flexible cable not
lighter than ordinary polychloroprene or
other equivalent synthetic
elastomer-sheathed cord (Code designation
60245 IEC 57) installed with the proper cord
anchorage to relieve conductors from strain,
including twisting, at the terminals and
protect the insulation of the conductors fr om
abrasion.
Beater RotationBeater rotation must be clockwise as
viewed looking into the freezing cylinder.
Note: The following repairs must be performed
by an authorized Taylor Servi ce Technician.
To correct rotation on a single-phase unit, change
the leads on the capacitor in the watt-control
electrical box. (See wiring diagram for details.)
To correct the rotation on a three-phase unit,
interchange any two incoming power supply lines at
the freezer main terminal block only.