Air Cooled Units
Air cooled units require a minimum of 3” (76 mm) of
air space on both sides, 3” (76 mm) at the rear, and
12” (305 mm) on the top of the unit. Minimum air
clearances must be met to assure adequate air flow
for optimum performance.
Water Cooled Refrigeration Units(Water Cooled Units Only)
On the back of the unit, two additional 3/8” (9. 5 mm)
F.P.T. water connections for condenser inlet and
outlet have been provided for easy hook-up. 3/8”
(9.5 mm) inside diameter water lines should be
connected to the machine. Flexible lines are
recommended, if local codes permit. Failure to use
adequate size water lines may cause the unit to go
on high head pressure and shut down.
Depending on local water conditions, it may be
advisable to install a water strainer to prevent
foreign substances from clogging the automatic
water valve.
DO NOT INSTALL A HAND SHUT-OFF VALVE ON
THE “OUT” LINE! Water cooled units ar e counter
flow and the water should flow in this order: First,
through the automatic water valve, second, t hrough
the inlet located at the bottom of the condenser, and
third, through the outlet fitting located at the top of
the condenser toanopentrapdrain.
IMPORTANT: Water pressures are pre-set at the
factory. Do not adjust the water pressure.
Improper water adjustments may cause operation
discrepancies.
Water Connections
An adequate cold water supply must be provided
with a hand shut-off valve. On the back of the unit , a
3/8” (9.5 mm) M.F.L. water connection has been
provided for easy hook-up. A flexible line is
recommended, if local codes permit. A minimum of
25 psi water pressure is required to avoid having the
unit cut out the low water pressure switch. A booster
pump must be provided if this pressure is not
available.
Note: Water lines beyond 200 ft. (61 m) require 1/2”
(13 mm) water lines.
INSTALL POTABLE WATER CONNECTION
WITH ADEQUATE BACK-FLOW
PROTECTION TO COMPLY WITH
APPLICABLE NATIONAL, STATE AND
LOCAL CODES.
It is always a good practice to have a filter system to
improve the quality of the water and to avoid
clogging the operating components.
IMPORTANT: The water filter (064422-SER) must
be thoroughly flushed with water before connecting it
to the machine. This removes any loose particles
present from the manufacture of the filt er that could
clog the flow control. To flush the filter, connect the
inlet end of the filter to the water supply. Posi tion the
outlet end of the filter over an empty pail. Open t he
water supply. Allow water to flow through the filter
until the water exiting the filter is clear. Close t he
water supply. Attach the outlet end of the f ilter to the
machine. Reopen the water supply.
Figure 1