31
Model C302 O perating Procedures
Pressing the MENU (SEL) key will give you the
option to sanitize the left cylinder. Move the c ursor
under the word “YES”. Pressing the MENU (SEL)
key at this time will start the flow of cleaner/sanitizer
through the syrup system into the freezing cylinder.
SANITIZE
LEFT SIDE YES NO
---
<- - --> SEL
Step 4
Repeat this procedurefor the right freezing
cylinder.
Note: Both sides of the machine have an LCD for
the two freezing cylinders located directly below it.
There is a left and a right freezing cylinder for each
LCD.
Step 5
Open the prime plugs. Allow each cylinder to fill
approximately 2/3 full. Close each prime plug.
Step 6
Continue filling the freezing cylinders with sanitizing
solution until the solution purges out of each relief
valve, and begins draining into the front drip tray.
The relief valves are located at the top of each mix
tank. Press the OFF (<- -) key.
Step 7
Press the BEATER (- - -) key to agitate the solution
in each freezing cylinder for five minutes.
Figure 44
Step 8
With a pail beneath the door spouts, open the draw
valves and drain all the solution from the the
freezing cylinders. Press the OFF (< - -) key and
close the draw valves.
Step 9
Repeat these steps for the other sid e of the
machine.
DisassemblyMAKE SURE THE CONTROL SWITCHES
ARE IN THE “OFF” POSITION.Failure to do so
may resultin personalinjury or component
damage.
Step 1
Open the draw valves to make sure all pressure has
been relieved.
Step 2
Open the prime plugs. Leave the prime plugs open
when removing the freezer doors to insure that all
pressure is relieved from the freezing cylinders.
Step 3
Remove the following parts from the freezer and
take them to the sink for brush cleaning.
Shandscrews
Sfreezer doors
Sbeater assemblies and scraper blades
Sdrive shafts and boot seals
Sfront drip tray
Ssplash shield