1800128430_01 _GV5010E0_110x154 30/11/12 11:54 Page14

PROBLEMS

CAUSES

SOLUTIONS

 

 

 

Water runs out of

The boiler is too full.

Do not fill the boiler right up to the

the holes in the

 

top.

soleplate.

 

 

 

 

 

Water streaks

Your ironing board is saturated with

A mesh type ironing board must be

appear on the linen.

water because it is not suitable for

used to allow any excess steam to

 

use with a steam generator.

escape.

 

 

 

White streaks come

Your boiler has a build-up of scale

Rinse out the boiler.

through the holes in

because it has not been rinsed out

 

the soleplate.

regularly.

 

 

 

 

Brown streaks come

You are using chemical descaling

Never add this type of product in the

through the holes in

agents or additives in the water for

water tank or in the boiler (see § “for

the soleplate and

ironing.

what water may be used”). Contact an

stain the linen.

 

Approved Service Centre.

 

 

 

 

Your linen is not rinsed sufficiently or

Ensure linen is rinsed thoroughly to

 

you have ironed a new garment

remove any soap deposits or chemicals

 

before washing it.

on new garments which may be

 

 

sucked up by the iron.

 

 

 

The soleplate is dirty

You are ironing at too high a

See our recommendations regarding

or brown and may

temperature.

temperature control setting.

stain the linen.

 

 

You are using starch.

Always spray starch on the reverse side

 

 

 

of the fabric to be ironed.

 

 

 

There is no steam or

The boiler is empty. (red light on).

Fill the boiler.

there is little steam.

 

 

 

The soleplate temperature is set to

The generator is working but steam is

 

the maximum.

very hot and dry As a consequence, it is

 

 

less visible.

 

The boiler is not yet ready.

After starting the appliance, wait for 6

 

 

minutes.

Steam escapes

The boiler cap has not been

Tighten the boiler cap correctly.

from the boiler cap.

tightened correctly.

 

 

The boiler cap seal is damaged.

Contact an Approved Service Centre

 

 

to order a new boiler cap seal.

 

 

 

 

The generator is faulty.

Stop using the generator and contact

 

 

an Approved Service Centre.

 

 

 

Steam or water

The generator is faulty.

Stop using the generator and contact

escapes under the

 

an Approved Service Centre.

appliance.

 

 

 

 

 

Environment protection first !

iYour appliance contains valuable materials which can be recovered or recycled. Leave it at a local civic waste collection point.

If you have any problems or queries please call our Customer Relations team first for expert help and advice:

0845 602 1454 - UK / (01) 677 4003 - Ireland

or consult our website - www.tefal.co.uk

14

Page 20
Image 20
Tefal manual Environment protection first, 180012843001 GV5010E0110x154 30/11/12 1154 Page14