Table 2-1. OMEGA CDMA Modem AC Power Supply Connector

Power Cable

Color Designation

Modem Terminal

Live

Black

1 (left pin)

 

 

 

Ground

Green

2 (center pin)

 

 

 

Neutral

White

3 (right pin)

 

 

 

Setting the OMEGA DIP Switch

The OMEGA CDMA Modem provides an 8-position configuration DIP switch that selects various operating parameters. Review the switch settings in Table 2-2 and change any to suit your requirements.

Table 2-2. OMEGA CDMA Modem Switch Settings

Switch

 

Description

 

ON

OFF

 

 

 

 

 

 

1

 

Baud Rate

 

Selects the OMEGA CDMA Modem baud rate. Set these

 

 

 

 

switches to match the speed of the attached DTE. See Table 2-3

2

 

 

 

 

 

 

for supported baud rates.

 

 

 

 

 

 

 

 

 

 

 

3

 

Parity

Async character: 8-E-1

Async character: 8-N-1

 

 

 

 

 

 

4

 

Sleep Mode (Reserved)

 

 

Set to OFF (default)

 

 

 

 

 

5

 

Interface Status or RSSI

LEDs display RS-232

LEDs display RSSI

 

 

 

 

signals (default)

 

6

 

Hardware Flow Control*

 

Enabled

Disabled (default)

 

 

 

 

 

 

7

 

DTR Dial

 

Enabled

Disabled (default)

 

 

 

 

 

 

8

 

RS-232/RS-485 Interface

 

RS-485

RS-232 (default)

 

 

 

 

 

 

9

 

2/4 wire RS-485

 

2-W Half-duplex

4-W Full-duplex

 

 

 

 

 

 

10

 

Reserved

 

Factory testing

Set to OFF (default)

 

 

 

 

 

 

* If your RTU or meter only supports TXD and RXD signals, set switch 6 OFF to disable hardware flow control. In this mode, the OMEGA CDMA Modem ignores the Request-To-Send and other input control signals.