28

Vega’s C-2002

7.7.2Incoming Select Call DTMF String Setup

The C-2002 has the capability of recognizing 3 different incoming DTMF strings on any line, monitored or not. When this programmable string is decoded, the unit will Un-mute the line for a programmable period of time (see Select Call Timer Duration Setup) to allow the remote user the opportunity to make a short transmission which the console operator can monitor. After the programmable period of unselect time has expired, the Unselect LED (Red led) for the line on which the DTMF string was decoded begins to flash and continues to flash until a PTT operation is completed on that line. This blinking light serves as a reminder to the console operator that a call was received and needs a response. Editing the incoming DTMF sequence is completed from the screen shown. The digits are entered with the DTMF keypad and the programmable keys; use the “D” key as save/enter function.

PROG1 – Enter the Edit Screen.

PROG2 – Selects DTMF decode screen.

PROG3 - Go to the sixth DTMF screen.

PROG4 - Return to Tone Settings Screen.

7.8 Function Tone Parameter Screen

7.8.1Function Tone Enabled/Disable

DTMF RX1: 1234

Edit Num next back

PROG1 PROG2 PROG3 PROG4

Pressing F1-F8 from the main setup screen enters the function tone parameter screen. The examples below appear

if F8 is pressed.

 

 

 

 

 

 

F8

Enabled

 

 

 

 

PROG1 - Toggle between the Enabled and Disabled.

 

Tgl

Tone

next back

 

 

 

 

 

 

PROG2 - Go to the Frequency programming screen.

 

 

 

 

 

PROG1

PROG2

PROG3 PROG4

 

PROG3 - Go to the Dual Frequency programming screen.

 

 

 

 

 

 

 

PROG4 - return to Opening Menu Screen.

 

 

 

 

7.8.2 Function Tone Setup

The top line of the display shows selected function number, the next item is the actual frequency of the function tone, followed by the duration of the tone in milliseconds.

PROG2 - Allows editing of the Frequency of the Function Tone. PROG3 - Allows editing of the Duration of the Function Tone. PROG4 - Returns to the previous menu.

F8: F=1250 D=40 Freq Dur back

PROG1 PROG2 PROG3 PROG4

7.8.3Frequency Programming Screen

The frequency programming screen will allow the user to change the value of the displayed function tone

PROG1 - Sets the value back to the default of 1950 Hz. PROG2 - Decreases the frequency by 1 Hz.

PROG3 - Increases the frequency by 1 Hz. PROG4 - returns to the function tone setup menu.

F8 Freq = 1950

1950 dwn up back

PROG1 PROG2 PROG3 PROG4

7.8.4Duration Display Screen

The Duration Display Screen shows the duration of the select function tone and displays it on the top line of the display for editing.

PROG1 - Sets the value back to the default of 40ms. PROG2 - Decreases the frequency by 1 ms. PROG3 - Increases the frequency by 1 ms.

PROG4 - returns to the function tone setup menu.

F8

Dur =

40

back

40

dwn

up

PROG1

PROG2

PROG3

PROG4

Page 34
Image 34
Telex C-2002 technical manual Function Tone Parameter Screen