Remote Control Console | 29 |
7.8.5Dual Function Tone mode Screen
The Dual Function Tone screen is used when operating the
PROG1 – Toggles between Enable/Disabled. PROG3 – Returns to Function tone screen. PROG4 - Returns to the Opening menu screen.
7.9 Supervisor Enable
Dual Tone: DISABLED
Tgl | next back |
PROG1 PROG2 | PROG3 PROG4 |
The supervisor function works in a manner similar to crossmute. It allows a single console to take control of all selected lines by disabling transmit on all other attached consoles. See section 4.2.2 for information on the wiring required to support this function. This function should only be enabled on consoles on which a supervisory function is appropriate.
PROG2 - Disables Supervisory Capability. | Super: Enabled | |
PROG3 - Enables Supervisory Capability. | prev next back | |
PROG1 PROG2 PROG3 PROG4 | ||
PROG4 - Return to top level menus. |
7.10 Alert Programming
The following appears if the ALERT button is pressed while the Opening Menu Screen is showing. This screen allows the technician to change the cadence of the alert tones. PROG1 selects between the two alert options. Alert 1 dictates which tone cadence will go out with the ALERT button. Alert 2 dictates which cadence will go out when the ALT button plus ALRT button is configured as a second alert tone.
The PROG2 button scrolls through the available cadencesAlert 1:1000Hz
A1/2 Cad edit back
PROG1 - Selects between Alert 1 and Alert 2. |
|
|
|
|
| |
PROG1 | PROG2 | PROG3 | PROG4 |
| ||
PROG2 – Selects |
|
| ||||
PROG3 - Allows editing of the level and frequency for the constant alert tone. |
|
|
|
| ||
PROG4 - return to the Opening Menu Screen. |
|
|
|
|
|
|
| Alert 1:1000Hz |
|
| |||
|
|
|
| |||
Cadence 1 is a steady programmable frequency. |
| Level Freq |
| back |
| |
Cadence 2 is a |
|
|
| |||
| PROG3 | PROG4 |
| |||
|
| PROG1 | PROG2 |
|
7.10.1 Cadence Level Selection
PROG1 - resets the level to the default of 0dBm.
PROG2 - decrements the level by 1 dBm.
PROG3 - increments the level by 1 dBm.
PROG4 - return to the Alert setup menu.
7.10.2 Cadence Frequency Selection
PROG1 - resets the frequency to the default value of 1000Hz. PROG2 - decrements the frequency by 1Hz (min freq of 0Hz). PROG3 - increments the frequency by 1Hz (max freq of 3500Hz). PROG4 - return to Alert Tone setup screen.
DTMF keypad - may be used to program the frequency.
Cad Lvl | = 0dB | back | |
0dB | dwn | up | |
PROG1 | PROG2 | PROG3 | PROG4 |
Cad Freq = 2050
1000H dwn up back
PROG1 PROG2 PROG3 PROG4