RamSan-500 User’s Manual 43 of 48
Figure 31 – Web Monitor Flash Module Failure Detection
Figure 31 shows the Web monitor detecting a single bad Flash module.
In this case, the module has been physically removed from the system
so the Web monitor is reporting it missing. The module icons in the
System List” show a warning icon on all suspect components. Both
raid2” and “Flash 2” have been noted with warning icons (yellow
triangled explanation points).
W
ARNING
R
EPLACE FAILED
F
LASH
M
ODULES AS SOON AS POSSIBLE
.
I
F A SECOND
F
LASH
MODULE FAILS IN THE SAME
RAID,
ALL DATA WILL BE LOST IN THE SYSTEM
.