Texas Memory Systems RamSan-500 manual Web Monitor Flash Module Failure Detection

Models: RamSan-500

1 48
Download 48 pages 62.42 Kb
Page 43
Image 43

Figure 31 – Web Monitor Flash Module Failure Detection

Figure 31 shows the Web monitor detecting a single bad Flash module. In this case, the module has been physically removed from the system so the Web monitor is reporting it missing. The module icons in the “System List” show a warning icon on all suspect components. Both “raid2” and “Flash 2” have been noted with warning icons (yellow triangled explanation points).

WARNING

REPLACE FAILED FLASH MODULES AS SOON AS POSSIBLE. IF A SECOND FLASH

MODULE FAILS IN THE SAME RAID, ALL DATA WILL BE LOST IN THE SYSTEM.

RamSan-500 User’s Manual

43 of 48

Page 43
Image 43
Texas Memory Systems RamSan-500 manual Web Monitor Flash Module Failure Detection