Thermo Products CDX3-125N, CDX3-75N, CHX3-75N Do Burners Stay Lit Past Proof Of Flame Check?

Models: CDX3-100N CHX3-100N CDX3-125N CHX3-125N CHX3-75N CDX3-75N

1 65
Download 65 pages 33.09 Kb
Page 57
Image 57
DO BURNERS STAY LIT PAST PROOF OF FLAME CHECK?

All installations and services must be performed by qualified service personnel.

DO BURNERS STAY LIT PAST PROOF OF FLAME CHECK?

YES

NO

IS IGNITOR

NO

POSITIONED CORRECTLY?

YES

CHECK AND CLEAN BURNERS

CHECK FOR PROPER LINE

AND MANIFOLD PRESSURE

REFERENCE GAS

PRESSURE CHART PAGE 31.

OK

CHECK FLAME PROB2

AND WIRE AND CHECK

POLARITY ON INCOMING

POWER AND GROUND

REPOSITION TO CORRECT LOCATION

IS W2 ENERGIZED?

NO

 

YES

DOES INDUCER

NO

 

 

GO TO

 

 

 

 

 

HIGH SPEED?

 

 

 

 

YES

DOES BURNER

NO

STEP TO HIGH FIRE?

IS THERE LINE

 

 

VOLTAGE ACROSS

NO

INDUCER POWER

 

TERMINALS "IND HI"

 

TO "IND N"?

 

 

 

YES

 

 

 

 

 

 

CHECK CONNECTIONS

TO INDUCER. IF OK,

REPLACE INDUCER.

IS THE HIGH FIRE

NO

PRESSURE SWITCH

 

CLOSED?

 

 

 

REPLACE

THE 50V61-143

CONTROL.

CHECK

CONTACTS

IN HIGH

FIRE SWITCH

AND FOR

BLOCKAGE IN FLUE. IF OK,

REPLACE DUAL

PRESSURE

YES

YES

SWITCH.

51

Page 57
Image 57