Thermo Products CHX3-125N, CDX3-75N, CHX3-75N Typical Internal Vent, Piping Arrangement for the

Models: CDX3-100N CHX3-100N CDX3-125N CHX3-125N CHX3-75N CDX3-75N

1 65
Download 65 pages 33.09 Kb
Page 26
Image 26
Figure 9: Typical Internal Vent

All installations and services must be performed by qualified service personnel.

leading away from the furnace must be composed of 3-inch diameter PVC pipe and pipe fittings only. Refer to item E in Figure 8.

b.After preparation of the internal 2-inch diameter PVC pipe sections, put a thin bead of a silicone rubber type sealant around the outlet flange of the inducer. Slip the 2-inch diameter PVC elbow (for the model series CDX3 in horizontal applications, a 2-inch diameter PVC tee) over the inducer outlet flange. Drive one (1) #8 x 3/4 inch sheet metal screw with black protective coating (supplied with furnace) through the elbow and into the outlet flange of the inducer to secure the elbow in place.

Figure 9: Typical Internal Vent

Piping Arrangement for the

Furnace Model Series CHX3.

Figure 10: Typical Internal Vent Piping Arrangement for the Furnace Model Series CDX3-100 / - 125.

Figure 11: Typical Internal Vent Piping Arrangement for the Furnace Model Series CDX3-100 / - 125 in RH Horizontal Applications.

c.Using PVC cement, glue the pre-cut 2-inch diameter thermoplastic pipe, from step (a) above, to the 2-inch diameter PVC elbow (for the model series CDX3 in horizontal applications, the 2- inch diameter PVC tee). Couple the drain tee assembly to the pre-cut 2-inch diameter PVC pipe using the reinforced rubber hose and the two (2) band clamps supplied.

20

Page 26
Image 26
Thermo Products CHX3-125N, CDX3-75N, CHX3-75N Typical Internal Vent, Piping Arrangement for the, Furnace Model Series CHX3