All installations and services must be performed by qualified service personnel.

Modifications to ECM blower speed settings are done using the S3 and S4 dip switch controls. Thermo Pride two-stage furnaces are factory shipped at the CFM settings listed below in Table 4C.

2-Stage Blower Settings (from factory)

Table 4C

Unit

Control Board

Heating

Heating

Constant Fan

Cooling

Dip Switch

CFM

CFM

CFM

CFM

 

Settings

(low fire)

(high fire)

 

 

 

 

SW3 1-4 Off

 

 

 

 

CDX3-75

SW4 1-3 Off

885

1012

500

1000

 

SW4 4 On

 

 

 

 

CHX3-75

SW3 1-4 Off

760

931

500

1000

SW4 1-4 Off

 

 

 

 

 

 

 

 

 

 

 

 

SW3 1-4 Off

 

 

 

 

CDX3-100

SW4 1-3 Off

1094

1340

600

1200

 

SW4 4 On

 

 

 

 

CHX3-100

SW3 1-4 Off

1015

1243

600

1200

SW4 1-4 Off

 

 

 

 

 

 

 

 

 

 

 

 

SW3 1-4 Off

 

 

 

 

CDX3-125

SW4 1-3 Off

1366

1673

700

1400

 

SW4 4 On

 

 

 

 

CHX3-125

SW3 1-4 Off

1270

1556

700

1400

SW4 1-4 Off

 

 

 

 

 

 

 

 

 

 

 

For adjustments to the Cooling CFM settings, as well as all additional CFM changes, please reference the dip switch tables listed in the ECM operation manual. (Included with every furnace.)

5.DE-HUMIDIFICATION

The ECM motor in conjunction with the W/R 50V51-843 has a feature to enhance de-humidification in the cooling mode. In the dehumidify mode the indoor blower motor (ECM) reduces CFM. By reducing airflow the indoor coil runs colder and thus extracts more moisture from the air.

The W/R 50V51-843 is shipped from the factory with dipswitch S5-2 set to on for system that do not have a dehumidification connection from the thermostat. For systems using a thermostat that provides dehumidification option move dip switch S5-2 to “OFF”. With the S5-2 switch in the “OFF” position the air conditioning fan speed will be reduced 30% from the normal CFM setting when the humidity in the home is higher than the set point of the dehumidistat.

6.FIELD WIRING AND REPLACING WIRING

Field wiring between the furnace and devices not attached to the furnace shall conform with the temperature limitation for Type T wire[63°F rise (35°C)] when installed in accordance with the manufacturer’s instructions. If any of the original factory supplied furnace wiring is replaced or a separate device other than the thermostat is wired internal to the unit 105°C thermoplastic or equivalent wire must be used.