All installations and services must be performed by qualified service personnel.
B. INITIAL START UP:
This furnace does not have a pilot. It is equipped with a hot surface igniter, which automatically lights the burner. Do not attempt to light the burner by hand. Check the following items before the initial
1.Check all wiring for loose connections and proper hook up.
2.Leak test gas piping connections.
3.Check all tubing to the pressure switch and drains to make sure they are connected firmly at all their connection points.
4.Check flue pipe, combustion air inlet and all PVC connections for tightness and to make sure there is no blockage.
5.Make sure air filter is in place.
6.Make sure the outside vent and air intakes are installed according to instructions and that they are free from blockage.
7.Make sure that the drain trap is properly connected to the furnace and to the buildings drain system.
OPERATING INSTRUCTIONS:
: Turn off power to furnace before it is placed into service. The gas piping system must have been leak tested by a qualified heating contractor. (See Section III, J, of these instructions on the installation of gas piping).
: It may be necessary to purge the air out of the gas line for initial
: Heat exchanger oil will burn off on initial firing creating an unpleasant odor. To prevent this odor from occurring more than once, it is suggested that:
1.A window(s) be opened.
2.The thermostat be set at highest setting.
3.The furnace remain running at conditions 1&2 for 30 minutes or until odor has dissipated.
39