Manual background

All installations and services must be performed by qualified service personnel.

IS THERE 24 VOLTS ACROSS "MVH" AND "MV COM" ON 50V51-843 CONTROL?

NO

REPLACE THE

50V51-843 CONTROL.

YES

IS THE VARIABLE SPEED AIR FAN OPERATING?

YES

CHECK CONNECTIONS

TO GAS VALVE. IF OK,

REPLACE GAS VALVE.

 

NO

 

 

 

 

NO

 

 

 

 

 

 

 

DOES BLOWER

 

 

 

 

SPIN FREELY?

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFERENCE ECM

 

 

 

OPERATION MANUAL

 

 

 

 

 

 

 

 

CONFIRM IF EITHER BLOWER WHEEL

IS RUBBING AGAINST HOUSING OR MOTOR SHAFT IS SPINNING FREELY AND REPAIR OR REPLACE AS NECESSARY

DOES SYSTEM RUN UNTIL THERMOSTAT IS SATISFIED?

YES

NO

IS LED LIGHT

ON 50V51-843

CONTROL FLASHING?

YES

REFERENCE LED

CHART ON PG. 48

OF THIS MANUAL.

NO

CHECK ALL WIRING FOR LOOSE CONNECTIONS.

53

Page 59
Image 59
Thermo Products 125n, chx-3 75n, 100n operation manual REPLACE THE 50V51-843CONTROL