Manuals
/
Thermo Products
/
Household Appliance
/
Furnace
Thermo Products
MO-425 manual Oil Furnace, General Service And Maintenance Manual, ECN 4392-MA
Models:
MO-425
1
1
20
20
Download
20 pages
49.62 Kb
1
2
3
4
5
6
7
8
<
>
Troubleshooting
Install
F. Wiring
B. Cad Cell Checkout Procedure
Page 1
Image 1
OIL FURNACE
GENERAL SERVICE AND MAINTENANCE MANUAL
FOR USE WITH THERMO PRIDE OIL FURNACES
THERMO PRODUCTS, LLC.
PO BOX 217
NORTH JUDSON, IN 46366
PHONE: (574)
896-2133
MO-425
ECN
4392-MA
Page 2
Page 1
Image 1
Page 2
Contents
OIL FURNACE
GENERAL SERVICE AND MAINTENANCE MANUAL
FOR USE WITH THERMO PRIDE OIL FURNACES
ECN 4392-MA
SECTION
TABLE OF CONTENTS
BEGINNING PAGE
NON-COMBUSTIBLEMATERIAL
COMBUSTIBLE MATERIAL
MAKE-UPAIR
II. INSTALLATION
A. CHIMNEY
1. PROPER CHIMNEY SIZE
2. PREVENTION OF CHIMNEY CONDENSING
3. PROPER CHIMNEY HEIGHT
4. PROPER VENT CONNECTOR PIPE/CHIMNEY CONNECTION
5. PROPER CHIMNEY BOTTOM LEVEL
7. TIGHT CLEAN-OUTDOORS AND CONNECTIONS
Fig. 5 Suggested method to improve chimney draft
6. TIGHT JOINTS
Required clearance with no protection from the
VELOCITY APPROXIMATELY 800 FEET PER MINUTE
C. DUCT WORK
1.HEATING CFM HEAT OUTPUT OF FURNACE BTUH
Fig. 8 Supply air duct sizing Example
1.1 X TR TEMPERATURE RISE, F = HEATINGCFM
EXAMPLES A. 110,000 BTUH OUTPUT
D. OIL TANK & PIPING
F. WIRING
E. OIL FILTER
Page
IRREPAIRABLE DAMAGE MAY RESULT
A. TROUBLE SHOOTING
III. DEALER MAINTENANCE
Page
Yes Yes
PROPER COMBUSTION ACHIEVED? NO
EFFECTS OF PRESSURE ON NOZZLE FLOW RATE
C. CLEANING OR REPLACING FLUE PIPES
B. CAD CELL CHECKOUT PROCEDURE
ON SHUT-DOWN
ON START-UP
?CAUTION Do not attempt to start burner when