Required clearance with no protection from the

All installations and services must be performed by qualified service personnel.

Fig. 7: Alternate constructions that allow reduced clearances to combustible materials.

REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION

Type of protection applied to and covering all surfaces of combustible material within the distance specified as the required clearance with no protection unless otherwise noted, all dimensions in inches, refer to Fig. 7.

Required clearance with no protection from the

18 inches

9 inches

 

6 inches

appliance or chimney connector is:

 

 

 

 

Sides &

Sides &

 

Sides &

 

Above Rear

Above Rear

 

Rear

a. 3-1/2" thick masonry wall without ventilation

--

12

--

6

--

5

air space….

 

 

 

 

 

 

 

 

 

 

 

 

 

b. 1/2" insulation board over 1" glass fiber or

12

9

6

5

4

3

mineral wool batts…

 

 

 

 

 

 

c. 0.024(24 gauge) sheet metal over 1" glass

9

6

5

3

3

3

fiber or mineral wool batts reinforced with wire

 

 

 

 

 

 

on rear face with ventilated air space…

 

 

 

 

 

 

 

 

 

 

 

 

 

d. 3- 1/2" thick masonry wall with ventilation air

--

6

--

6

--

6

space..

 

 

 

 

 

 

 

 

 

 

 

 

 

e. 0.024 (24 gauge) sheet metal with ventilated

9

6

5

3

3

2

air space.

 

 

 

 

 

 

f. 1/2" thick insulation board with ventilation air

9

6

5

3

3

3

space..

 

 

 

 

 

 

g. 0.024 ( 24 gauge) sheet metal with ventilated

9

6

5

3

3

3

air space over 0.024 (24 gauge) sheet metal with

 

 

 

 

 

 

ventilated air space….

 

 

 

 

 

 

 

 

 

 

 

 

 

h. 1" glass fiber or mineral wool batts

9

6

5

3

3

3

sandwiched between two sheets 0.024 (24 gauge)

 

 

 

 

 

 

sheet metal with ventilated air space

 

 

 

 

 

 

 

 

 

 

 

 

 

A.Equal the required clearance with no protection.

B.Equals the reduced clearance permitted in accordance with the preceding clearance chart.

C.The protection applied to the construction that covers the combustible material should extend far enough in each direction to make C equal to A.

6

Page 8
Image 8
Thermo Products MO-425 manual Required clearance with no protection from the