ASSEMBLY

ASSEMBLY

DANFOSS VALVE PLUMBING (WITH MID-MOUNT VALVE)

A priority valve will be used to power the danfoss lift valve. The tractor ports used are on the selective control valve (SCV) and the Mid-Mount Valve. The SCV is located between the right arm of the three point hitch and the axle. The Mid-Mount valve is located under the right front corner of the cab. The power beyond port is located on the bottom of the Mid-Mount valve towards the front. The excessive flow port is located on the underside of the SCV. The return port is accessed through the end of a run tee located on the SCV. See the danfoss lift valve page in the parts section for hardware and location of parts. Refer to the image below as a guide.

SCV

MID-MOUNT VALVE

The power beyond port uses the existing adapter for the pressure hose. That hose is routed to the “P” port of the priority valve. Next the hose from the “CF” port on the valve goes to the “P” port on the danfoss lift valve. The return hose from the lift valve is connected to the closest end on the run tee of the “T” port on the selective control valve. Plumb the excessive flow hose from the “EF” port on the priority valve to the “EF” port on the SCV. Then the load sense hose goes from the “LS” port on the priority valve to the “LS” port on the lift valve. Refer to the illustration below for port call-outs on the danfoss priority valve.

Assembly Section 2-9

Page 43
Image 43
Tiger Products Co., Ltd JD 5083E, JD 5101E, JD 5093E manual Assembly Danfoss Valve Plumbing With Mid-Mount Valve