SA41 ELECTRICAL SPECIFICATIONS

INVERTER TYPE PWM Full bridge power stage, with true sine wave AC output.

DEMAND START SECTION

 

 

Type:

 

Pulsing AC

Minimum Load Power to start (User adjustable):

 

3W to 20W

Maximum response time:

 

1 sec

Standby current from battery (Average):

 

60mA

BATTERY VOLTAGE RANGE

 

 

Low DC Volts Disconnect (Instantaneous):

 

34V

Low DC Volts Cutout (Delayed, User Adjustable):

38-44V

Low DC Volts Cut-in (Delayed, User Adjustable):

44.4-52V

High DC Volts Cutout (Instantaneous, User Adjustable):

60-68V

High DC Volts Disconnect (Instantaneous):

 

70V

TOTAL APPLIANCE RATING AT

25°C

40°C

Continuous:

3000W

2800W

30 Minute rating:

4700W

4400W

5 Minute rating:

5300W

 

1 Minute rating:

6500W

 

Surge rating:

8500W

 

INVERTER EFFICIENCY

 

 

Peak (at 500W):

 

91%

No load power consumption (C0NT mode):

 

0.66 A

MISCELLANEOUS SPECIFICATIONS

 

 

Output Frequency Accuracy:

 

50Hz ± 0.001 %

Output Voltage Accuracy (0 - 2200W)

 

240V ± 4 %

Total Harmonic Distortion (THD)

 

< 4 %

Control Outputs 1 & 2, max DC sinking current:

 

50 mA

Alarm Inputs 1 & 2, input switching level:

 

HI > 3 V

 

 

LO < 1 V

Operating temperature range:

 

-10°C to 50°C

Weight:

 

32 kg

DC Input is Electrically Isolated from AC Output

Note: Through a policy of continued development, specifications are subject to change without notice.

The above specifications are based on unity power factor.