NETT AMP HOURS TODAY

Net AH : 69 IN

- - - Today - - -

BATTERY CHARGE

Charge : 87%

- - - In Battery - - -

This reading gives a nett figure of Amp Hours since midnight last night. A nett AH reading of IN indicates more Amp Hours have gone into the battery than have been used. The opposite applies for a Net AH reading of OUT.

1 Amp Hour = 1 amp for 1 hour, or 2 amps for ½ hour, etc.

This reading shows the amount of charge present in you battery bank at any given time. i.e. 100% means a fully charged battery.

MINIMUM CHARGE

With the optional current shunt (SA-S200) installed, the minimum charge in your batteries today, this week or for a number of weeks or days can be logged (Minimum daily discharge). Minimum charge readings are accessed by pressing the UP and DOWN keys together for 1 second.

These vital readings give you the information you need to maximise your battery life. This is done by managing your loads to maximise this figure, e.g. using heavier loads later in the day or at other times when the battery charge is high.

MINIMUM CHARGE TODAY

MIN CHARGE : 76%

- - - In Batt Today - - -

The minimum charge in the battery since midnight last.

MINIMUM CHARGE THIS WEEK

MIN CHARGE : 76%

- - - In Batt This Wk - - -

The minimum charge in the battery since midnight last Saturday.

MINIMUM CHARGE WEEKLY LOG

Weeks ago : 1

Min Charge : 76%

This displays a log of the minimum weekly charge in the battery for up to 52 weeks. The logged weeks may be stepped through by pressing the UP or DOWN key. The weeks that have not logged AH as yet will display 255%.

MINIMUM CHARGE DAILY LOG

Days ago : 1

Min Charge : 76%

This displays a log of minimum daily charge in the battery for up to 30 days. The logged days may be stepped though by pressing the UP or DOWN key. The days that have not logged AH as yet will display 255%.