Toro SA41 owner manual Fault Finding, Heatsink TOO HOT, Alarm 1 Active, Alarm 2 Active

Models: SA41

1 30
Download 30 pages 20.77 Kb
Page 15
Image 15

HEATSINK TOO HOT

HS Too Hot : 82C

If the heatsink reaches its maximum operating temperature, the SA41 will

** Press a Key * * shut down to protect itself. The SA41 will come on again only when the temperature drops to a safe level. The present temperature of the heatsink is also displayed.

ALARM 1 ACTIVE

Alarm 1 Active : * * Press a Key * *

When the Alarm 1 input on the SA41 is activated, (see "Settings" on page

12)this message is displayed and the buzzer sounds. The buzzer will continue to sound as long as the input is active.

ALARM 2 ACTIVE

Alarm 2 Active :

When the Alarm 2 input on the SA41 is activated, (see "Settings" on page

** Press a Key * * 12) this message is displayed and the buzzer sounds. The buzzer will continue to sound as long as the input is active.

LOW CHARGE ALARM

Lo Charge : 59%

If the battery charge drops below the ‘Min charge’ setting, and the ‘Lo

** Press a Key * * Chg alarm’ setting is set to ‘ON’ then this alarm will sound. You are then able to take appropriate action such as removing loads or starting a generator to prevent further discharge and possible damage to your batteries.

FAULT FINDING

1. INVERTER STAYS ON EVEN WHEN NO APPLIANCE IS BEING USED.

This can be a common problem known as a "phantom load", but can be easily overcome with ENERGY MANAGEMENT. Some appliances will need to be switched off at the power point as they may still represent a small load despite being switched off at the appliance. Check again to make sure there are no appliances left on, then sequentially switch off appliances at the wall and by watching your night light (as described in "Handy Hint" on page 19), check to see if the SA41 returns to pulsing mode (after a 10 second delay). Once you have found the offending appliance, adjust the sensitivity of the demand start up (see set parameters) until the inverter turns off. Once this is done re check that small loads will still bring the inverter on when required.

2. INVERTER WILL NOT COME ON WHEN SMALL APPLIANCE IS SWITCHED ON.

This means that your demand start sensitivity is set too high. With the appliance in question switched on, adjust the demand start sensitivity until your SA41 turns on. See Demand Start Sense on page 10.

15

Page 15
Image 15
Toro SA41 owner manual Fault Finding, Heatsink TOO HOT, Alarm 1 Active, Alarm 2 Active