Chapter 3 Handling

3.1.3Power Off with Windows

If a power supply is turned off without shutdown of Windows, the data in a hard disk is destroyed and it may be unable to reboot.

Model 2000 is supporting the automatic shutdown of Windows, and the power supply off-sequence. If the power supply module of exclusive use is used, the shutdown of Windows can be performed without carrying out operation of a mouse and a keyboard.

Important

In order to use an automatic shutdown function, the RAS support software installed in C2 as standard is required.

3.1.4Power Supply module PS694 with Battery

Power Supply Module PS694

C2

Windows

Detect AC Failure

Shutdown Sequence

Shutdown

Request

RAS driver

AC100/240V

Main circuit

Battery

Control

Shutdown

Request

Power control signal

Main power for controller

Operation during power off

(1)An AC input power failure exceeding the preset allowable limit is detected as a power failure. (Normal operation continues if power fails shorter than that.)

(2)Shutdown is requested to the C2 and the C2 starts shutdown processing.

(3)When the C2 finishes shutdown processing, the power module PS694 cuts power off by stopping power supply from the battery.