1.3 Installation Requirements
1.3 Installation Requirements
Observe the following when planning and designing the installation environment.
The installation environment must satisfy the conditions described below.
Item | Hard Disk Drive model | Flash Disk Drive model | |
Operating ambient | 5 – 40oC |
| 0 – 50oC |
temperature |
|
|
|
Storage |
| ||
temperature |
|
|
|
Relative humidity | 10 to 90%RH, no condensation | 5 to 90%RH, no condensation | |
Dust density | 10mg/m3 or less |
| |
Corrosion | No corrosive gas is present. |
| |
resistance |
|
|
|
Vibration resistance | 1.96m/s2 (0.2G) continuously | 9.8m/s2 (1G) continuously for | |
| for 30 minutes in X, Y, Z | 30 minutes in X, Y, Z direction | |
| direction |
|
|
Shock resistance | 98m/s2 (10G) 3 times each X, Y, | Z direction | |
Usable altitude | Up to 2000m |
| |
Dielectric strength | 1500Vac/1 min. |
| |
Ambient | No corrosive gas is present. |
| |
atmosphere |
|
|
|
Structure |
| ||
Cooling | Natural air cooling |
| |
EMC | 6 KV | : Static electricity discharge resistance | |
| 10 V/m | : Radiation field |
|
| 2 KV/1 KV/0.25 KV: Fast transient | ||
Grounding | Grounding resistance 100Ω or less |
1
6F8C1111 | 5 |