Important

If the running application cannot be terminated normally for some reason or other, Windows is forcibly terminated subject to the completion waiting time set with the RAS driver.

In this case, the file data of application or Windows may be destroyed. Fully confirm application operation in advance that it is free of problems.

Important

If an input power supply is turned off during Windows starting, power supply OFF may be carried out without carrying out shutdown processing.

Important

When it mounts two or more sets of C2 in one base unit, after all C2 carries out the completion of a shutdown, power supply OFF is carried out.

Operation after power recovery

If AC power is restored during the shutdown processing, power is automatically turned back on after the operation described in step (3).

Hold time and charge time of a built-in battery

The battery's hold time is 4 minutes maximum (when the battery is fully charged and operates at the rated output level). A recharge of about 2 hours is necessary for the battery to make up for the loss of its capacity by a single Windows shutdown after AC input power is back on.

Important

When battery capacity runs short during battery operation, a power supply is turned off compulsorily.

In this case, the file data of application or Windows may be destroyed. Do not repeat OFF of an input power supply.

Important

• PS694 is not a thing supposing use in the inferior input power supply state.

Battery operation is performed, while the input power supply turns off, even if it is less than the set-up time at the time of retentive power interruption.

When there is extremely much generating frequency of a power interruption, the charge capacity of a battery runs short and power supply OFF may be carried out before the completion of a shutdown at the time of input power supply OFF.