4.3 Replacement Timing of Major Parts

CAUTION

Take extreme precaution when measuring the power supply voltage at the power supply terminal of the module during inspection.

There is a danger of electrocution.

Do not touch the C2 module when the power is on. The heat radiating side covers become extremely hot (ambient temperature+20oC) when power is on. It cools (ambient temperature+10 oC) in 10 minutes when the power is turned off.

4.3Replacement Timing of Major Parts

Listed below are the product life of major components. Periodically replace parts using this table as reference. Contact your Toshiba service desk for information concerning the price and ordering method of replacement parts.

Product life of major components

 

Parts

 

 

Location of

 

 

Description

 

 

Product Life

 

 

Replacement

 

 

Action

 

 

 

 

wear

 

 

 

 

 

 

Interval

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hard disk

Mechanism

 

Wear

5 years or 20,000

2 years

Replace

 

drive

 

 

 

 

 

 

cumulative power on hours

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

which ever comes first.

 

 

 

 

 

 

 

Battery

Capacity

 

Depletion

500 power interruptions or

Replace

 

(PS694 built-in

 

 

 

 

 

 

3 years, whichever come

 

 

 

 

 

 

 

Ni-Cd)

 

 

 

 

 

 

first. (Ambient temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35o C)

 

 

 

 

 

 

 

Battery

Capacity

 

Depletion

450 power interruptions or

Replace

 

(PS694M

 

 

 

 

 

 

1 year, whichever come

 

 

 

 

 

 

 

built-in Ni-MH)

 

 

 

 

 

 

first. (Ambient temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35o C)

 

 

 

 

 

 

 

Battery

Capacity

 

Depletion

10 years (Ambient

10 years

Parts replacement

 

(C2 built-in)

 

 

 

 

 

 

temperature 35o C)

 

 

 

by overhaul

 

PC Card slot

Functional

 

Wear

10000 insertions/removals

Parts replacement

 

 

 

 

parts

 

 

 

 

 

 

 

 

 

 

by overhaul

 

External FDD

Mechanism

 

Wear

5 years or 15,000

2 years

Replace

 

 

 

 

 

 

 

 

 

 

cumulative power on hours

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

which ever comes first.

 

 

 

 

 

 

 

 

 

 

 

Product life of major components

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parts

 

 

Location of

 

 

Description

 

 

Product Life

 

 

Replacement

 

 

Action

 

 

 

 

 

wear

 

 

 

 

 

 

Interval

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Keyboard

Mechanism

 

Wear

100,000 strokes

Replace

 

Mouse

Mechanism

 

Wear

100,000 clicks

Replace

 

CRT

Displays

 

 

 

 

10,000 cumulative power

Replace

 

 

 

 

 

 

 

 

 

 

on hours

 

 

 

 

 

 

 

In addition to the main unit, disk drives such as the CD-ROM, and MO drive also have a product life. Check the product life of the peripheral devices being used and replace them before their product life expires.