e-STUDIO5520C/6520C/6530C © 2008 TOSHIBA TEC CORPORATION All rights reserved
2-46
2. Copier-specific Adjustments
* The smaller the setting value is, the weaker the sharpness intensity becomes. The larger the setting value is,
the stronger the sharpness intensity becomes.
Changing the values for these codes will change the sharpness intensity, when the "Sharpness" indicator in
the "IMAGE" menu is set to the center. Remember that 1 step of the indicator will increase or decrease the
sharpness intensity by 25. If the sharpness intensity of the center value is changed, each step of the
indicator will be changed accordingly. (For instance, if the center value is decreased by 25 (softer), the
value of each step of the indicator will also be decreased by 25 (softer).)
However, the range of adjustment values that is valid for sharpness level change is from -100 to +100 of
the total of the setting value of the adjustment code and that of the indicator. For instance, if the setting
value of the adjustment code is "103" (-25 from the default value), the limit of the steps in the soft side of
the indicator is "-3". If the step is set at "-4", the image quality will not be changed.
<Note> "Minimizing the edges of the copy image" and "Sharpening the copy image" are mutually
contradictory. When the adjustment is performed to minimize the edges, the resolution of the
copy image may decrease.
After decreasing the sharpness intensity, copy and check the copy image quality.
If further image quality adjustments are still necessary, use the next procedure.
Since "-25" is assigned to the center, the image quality
remains the same even if the indicator is changed from
"-3" to "-4".
Setting value "103":
Default:
Soft Sharp
+3
+50
+75
|
+1
0
+25
|
0
-25
0
|
-2
-75
-50
|
-4
-100
-100
|
+4
+75
+100
|
+2
+25
+50
|
-1
-50
-25
|
-3
-100
-50
|
Assigned adjustment
value of sharpness