2. Specifications
2.1 General specifications
Item | Specifications | Remarks |
Power voltage | 5 Vdc (supplied from back plane bus) |
|
Current consumption | 1.0 A (5 Vdc) maximum | Note (1) |
Environmental conditions | Conforms to T3 specifications |
|
Insulation resistance | 10 MΩ (500 Vdc) | Note (2) |
Withstand voltage | 500 Vac - 1 minute | Note (2) |
Size | T3 I/O module size (1 slot) |
|
Weight | 500 g |
|
Note (1) The T3’s power supply module can supply maximum 7 A of internal 5 Vdc. Check that the internal 5 Vdc current consumption per one power supply module does not exceed the limit.
Note (2) Between interface connector pins and internal circuit.
2.2 Functional specifications
| Item | Specifications |
|
| Module type | Serial communication interface |
|
| I/O allocation type | iX+Y 4W |
|
| Buffer memory capacity | 448 words x 4 |
|
|
| (accessed from T3 by READ/WRITE instruction) |
|
| Transmission interface | 2 channels; |
|
|
| Channel 1 … |
|
|
| Channel 2 … |
|
| Display | Status LEDs; |
|
|
| RUN … lit when operating normally |
|
|
| TX1 … lit while transmitting data from channel 1 |
|
|
| RX1 … lit while receiving data to channel 1 |
|
|
| TX2 … lit while transmitting data from channel 2 |
|
|
| RX2 … lit while receiving data to channel 2 |
|
| Connectable devices | Computer, bar code reader, display device, sensor, |
|
|
| printer, or other serial ASCII device |
|
| RAS function | Self diagnosis, watch dog timer (200 ms), |
|
|
| transmission error check, etc. |
|
|
|
|
|
|
|
|
|
16 ASCII Interface Module (AS311)