9. ROGRAMMING PROCEDURES

9.13 CMT/PL-3

PL-3 Operation

Connect the PL-3 to the H-9000 by using RS-232C Cable, then turn on the power of the H-9000 and the PL-3.

Insert a data disc into the PL-3 and adjust the transmission rate to the H-9000 ( 7 2 :4800

BPS or

7

3 : 2400 BPS) by using the rotary switch.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the

 

key of the PL-3, then check whether the SAVE LED is on.

SAVE

 

 

 

 

 

number of the data disc by using the rotary switch.

Program the file

(

4

1

: File No. 1,

4

2

: File No. 2,

4

8

: File No. 8,

4

9

: File No.9)

<MENU>

Page 2

2

Set the transmission item.

(Refer to table 4)

 

NEXT

or

 

 

PLU

 

SAVE

or

LOAD

ENTER

PROG.

ESC.

<MENU>

Page 2

Main

<MENU>

NOTES: 1. Press SAVE or LOAD key on the PL-3.

2.In the event Enter Key is not pressed within 10 seconds after key is pressed, the Time Out Error results.

SAVE

or

LOAD

3.After pressing the ENTER key, the operation ends when 00appears in the 7 seg. display and LAMP goes off. Remove the data disc and turn the power off.

Table 3: Error code during PL-3 operation

Error Code

Error Message

 

0

FDC ERROR

 

1

FDK MISINSERTION ERROR

 

2

UNAVAILABLE FDK INSERTION

1

 

ERROR

 

3

VOL. LABEL UNMATCH ERROR

 

4

FDK MEMORY FULL ERROR

 

5

WRITE PROTECT ERROR

 

6

NO SEARCH FILE ERROR

 

1

TIME OUT ERROR

 

2

LOAD ERROR

3

3

FDK ERROR

 

4

BUSY STATUS

 

5

POWER FAIL ERROR

 

 

 

 

6

OVERRUN ERROR

Error Code

Error Message

3

7

FRAMING ERROR

8

PARITY ERROR

 

 

 

 

 

0

DATA ERROR

 

1

STATUS ERROR

7

 

 

2

TIME OUT ERROR

 

3

FDK READ/WRITE ERROR

 

 

 

 

F

DESIGNATED SELECT KEY

 

 

ERROR

 

 

 

 

0

RAM READ/WRITE ERROR

 

1

ROM CRC ERROR

8

 

 

2

RAM BACK UP BATTERY ERROR

 

3

FDC DIAG LEVEL 0 ERROR

 

 

 

 

E

SYSTEM FDK LOADING ERROR

 

F

SYSTEM ERROR

 

 

 

1)When the error code in FF, this system enters stop status. (Turn the power off/on for release.)

2)When the error code is F2 or FE, perform the status clear ( 9 9 ).

3)If an error occurs, refer to the PL-3 Owner’s Manual and solve the problem.

9- 21

Page 43
Image 43
Toshiba H-9000N-US Error code during PL-3 operation, PL-3 Operation, Number of the data disc by using the rotary switch