RETURN 1/4
DELETE (A) 1/2
INSERT 1

9.PROGRAMMING PROCEDURES

9.2 PLU DATA SETTING

Pressing the key instead of the ENTER key returns to the preceding menu. Verification label of PLU data

key advances to the next menu. Pressing the

(W: Weigh, F: Fix, B: By-count) (C: Compulsory, Blank: Not compulsory)

NOTES:

1. A UPC code is made up of a combination of an entered code and an AUTO CODE. Be

sure to attach some

 

 

 

characters to the end of the AUTO CODE, or all entered codes

 

 

 

will be ignored and an AUTO CODE will become an UPC code (see ex. 1).

ex. 1) enter code:

456

 

ex. 2) enter code: 4567

ex. 3) enter code: 123456

AUTO CODE:

123---

AUTO CODE: 123---

AUTO CODE: 987

 

 

 

code#: 123456

 

 

 

code#: 123567

code#: 987

2.When there is no area to store PLU data, an error occurs when pressing the ENTER key.

3.Changing a PLU # to the number to which other PLU data is set will result in an error.

4.Unit price flag may be selected as follows:

a.

b.

key : $ per lb

key : $ per 1/2 lb

c.key : $ per 1/4 lb

5.Tare limit should be a multiple of 5, up to 2.000 lb for US type.

6.Safe handling instructions can be printed on 57-mm wide labels only. Safe handling instructions are printed on labels formatted for ingredient messages. Only ingredient message labels with 13 or more lines can be used to print safe handling instructions. Available print formats are as follows:

13 (63), 15 (65), 16 (66), 23 (73), 25 (75), 26 (76), 33 (83), 35 (85), 36 (86), 41, 42, 43, 48 and 49.

7.Tare % indicates a percentage of tare in gross weight, which is available when the initial Setting #28-4 is set to 1.

8.When setting open prices in the count mode (Initial Setting #1-6: 1), set zeros as quantity and unit price.

9- 6