12. OPERATING PROCEDURES

12.6 TARE/SAVE FUNCTION PROCEDURES

12.6TARE/SAVE FUNCTION PROCEDURES

NOTE: This operation is available only when the optional scale unit is connected.

Menu:

REG., M.DOWN, or REWRAP

Mode:

WEIGH or FIX (Tare % function is available in WEIGH mode only.)

There aretwo kinds of tare subtraction procedures, one is “Direct tare”, the other is “Preset tare “.

The

SAVE

key is used to save the tare, unit price, and PLU data after taking a commodity from the

platter.

 

 

 

 

Tare %

 

 

 

0.200 lb

2

0

0

 

 

 

 

 

 

Place a container on

 

 

1

0

0

 

the platter.

 

 

 

 

(Ex. 0.200 lb)

 

T

Press:

 

 

 

 

 

 

 

 

 

 

T

 

 

 

%

 

 

Press:

 

 

 

 

 

 

 

 

 

 

Place a container

 

 

 

 

 

 

 

on the platter

 

 

Enter the PLU #.

1

0

0

 

Tare %

Press:

PLU

%

The PLU data and tare are

SAVE

saved.

Place a commodity on the platter.

(Ex. 1.000 lb)

1

0

0

 

 

 

%

Remove the Commodity together with the container.

 

Press:

C

 

 

CA type

 

 

US type

 

 

 

 

 

 

 

 

MANUAL:

:AUTO

PLU Press:

0

Press:

* The label is issued.

T Press:

Press:

C

 

 

 

 

 

 

Remove the commodity together with the container.

PLU

Press:

NOTES: 1. Tare subtraction is available up to 2.000 lb. When tare subtraction is in operation, however, the scalable range for net weight becomes less by the amount of the tare. (Net weight-Grossweight-Tare)

2.Preset tare must be a multiple of 0.005 lb.

3.The tare % function is available when the Initial Setting #28-4 is set to 1. The speed key #70 will function as the % key (Refer to page 5-3). Set a tare % within the range from 0.0 to 99.9.

4.When a commodity is placed on the platter and the calculated tare exceeds the maximum, a “TARE WEIGH OVER” error will occur.

12-11