12. OPERATING PROCEDURES
12.6 TARE/SAVE FUNCTION PROCEDURES
12.6TARE/SAVE FUNCTION PROCEDURES
NOTE: This operation is available only when the optional scale unit is connected.
Menu: | REG., M.DOWN, or REWRAP |
Mode: | WEIGH or FIX (Tare % function is available in WEIGH mode only.) |
There aretwo kinds of tare subtraction procedures, one is “Direct tare”, the other is “Preset tare “. | |||||||
The | SAVE | key is used to save the tare, unit price, and PLU data after taking a commodity from the | |||||
platter. |
|
|
|
| Tare % |
| |
|
| 0.200 lb | 2 | 0 | 0 |
| |
|
|
|
| ||||
| Place a container on |
|
| 1 | 0 | 0 | |
| the platter. |
|
|
| |||
| (Ex. 0.200 lb) |
| T | Press: |
|
| |
|
|
|
|
|
| ||
|
| T |
|
|
| % |
|
| Press: |
|
|
|
|
| |
|
|
|
|
| Place a container |
|
|
|
|
|
|
| on the platter |
|
|
Enter the PLU #. | 1 | 0 | 0 |
|
Tare %
Press:
PLU
% |
The PLU data and tare are | SAVE |
saved. |
Place a commodity on the platter.
(Ex. 1.000 lb)
1 | 0 | 0 |
|
|
|
% |
Remove the Commodity together with the container.
| Press: | C |
|
| |
CA type |
|
| US type | ||
|
| ||||
|
|
|
|
|
|
MANUAL:
:AUTO
PLU Press: | 0 | Press: |
* The label is issued.
T Press: |
Press: | C | |
|
|
|
|
|
|
Remove the commodity together with the container.
PLU
Press:
NOTES: 1. Tare subtraction is available up to 2.000 lb. When tare subtraction is in operation, however, the scalable range for net weight becomes less by the amount of the tare. (Net
2.Preset tare must be a multiple of 0.005 lb.
3.The tare % function is available when the Initial Setting
4.When a commodity is placed on the platter and the calculated tare exceeds the maximum, a “TARE WEIGH OVER” error will occur.