( 3 ) Using the unit with external sync signal

When adjusting H (horizontal) phase refer to the item "7.2 (5) (5.1) Adjusting horizontal phase".

(3. 1) H (horizontal) phase adjustment

Observe the external sync signal and the LVAL signal output waveform of the unit with a dual trace oscilloscope, and ad- just H phase so that the H phases match.

External

Sync. signal Match

the phase.

LVAL signal output

7. 4 Synchro. Scan Operation

The shutter speed can be set by the horizontal scanning period (1H) or by the frame.

( 1 ) Setting by 1H

1H/796H to 795H/796H (1H/387H to 386H/387H when partial scanning at 60fps, E.60fps 1H/258H to 257H/ 258H when partial scanning at 90fps, E.90fps) stands for the setting by the 1H and the shutter speed can be set by the 1H (43.05 s).

( 2 ) Setting by the frame

2FRM to 512FRM stand for the setting (long period exposure) by the frame.

The video signal stored during the frame period set is output as 1 frame video image at a frame interval specified.

(Internal VD)

RGB data (video interval image)

FVAL

LVAL,

DAVL

n

n+1

(4FRM setting)

23