(3. 2) Pulse Width Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)

Trigger*1

About 1 s

About 7 s

 

 

 

 

Exposure period*2

(Internal VD)*3

RGB data (video interval image)

FVAL

LVAL,

DVAL

28H (Partial scanning OFF)

38H (Partial scanning 60fps)

47H (Partial scanning 90fps)

Negative polarity mode

Positive polarity mode

Exposure period*2

*1: Externally input signal

*2: Exposure time = Trigger pulse width + 6 s

(Valid trigger pulse width is 2 s or greater for external trigger shutter operation.)

*3: As long as there is no external sync input, the internal VD will be output when SJ01 is set to HD/VD output position.

*4: Video is output at the falling edge of the internal VD following completion of the exposure period. The video and FVAL/LVAL/DVAL have a paired relationship.

Note:

When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.