( 2 ) 1P SR (1 Pulse Trigger Sync Reset)
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, the vertical sync signal is reset and frame images are output.
(2. 1) 1 Pulse Trigger SYNC-RESET Picture Output Timing
Negative polarity mode
Trigger*1
Positive polarity mode
About 1 ∝s
Exposure period*2
Exposure completion
0 to 1H*3
(Internal VD)
RGB data (video interval image)
FVAL
LVAL,
DVAL
28H (Partial scanning OFF)
38H (Partial scanning 60fps)
47H (Partial scanning 90fps)
*1: Externally input signal
*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro- nized to this and output.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.
26