Toshiba kV-9168A Alarm Recording, Operation at Alarm Input, Event Recording, Alarm Recall Display

Models: kV-9168A

1 52
Download 52 pages 223 b
Page 30
Image 30

PREPARATIONINTRODUCTION

ALARM RECORDING

If an alarm condition arises, the alarm function operates with an alarm input signal.

Operation at Alarm Input

When there is an alarm during recording, recording pause or stop modes, the VCR automatically goes into alarm recording mode. The VCR can be programmed to record in the following time modes during alarm recording: SPA2, EPA6, SPA12, EPA18, SPA24.

Alarm input

 

 

 

 

Recording

SPA2, EPA6,

SPA12,

Recording

Recording pause

Recording pause

EPA18, SPA24 mode

Stop

Stop

 

 

 

 

 

 

Alarm Recording

iWhen there is an alarm input in the STOP mode, a slight delay will occur in start of the alarm recording.

iWhen the pause mode continues for 10 minutes the VCR goes to the stop mode. This occurs in order to protect the video heads and tape. While in pause mode, the video head is constantly tracing the same location.

iAlarm recording will not operate from power off mode and timer standby mode.

RECORDING

OPERATION

 

 

PLAYBACK

OPERATION

 

 

Event Recording

If event recording is desired, set the VCR’s recording mode to SPL01, SPL02 or SPL03. In order to accomplish this press the time mode button until “SPL01”, “SPL02” or “SPL03” is shown.

If there is no alarm input present when in “SPL01”, “SPL02” or “SPL03” mode, the VCR automatically forwards 2 fields with recording every appointed time (SPL01: 1min, SPL02: 2min, SPL03: 3min.) to protect the tape and the video head from damage.

Warning at Alarm Recording

When an alarm signal is input, the buzzer sounds and the alarm display on the VCR DISPLAY lights.

Alarm display lights and then blinks when alarm recording is finished.

 

ALARM

H

 

 

 

 

 

 

REC

SP

 

 

 

 

 

 

 

 

 

 

 

The day of the week display

 

 

 

 

changes to the alarm number

 

Changes to a display of SPA2, EPA6, SPA12,

8/28/97 A01

during alarm recording.

 

 

 

EPA18 or SPA24.

 

17:30:13SPA 2 Changes to a display of SPA2,

 

 

 

• Turn off the BUZZER switch to stop the buzzer.

 

 

EPA6, SPA12, EPA18 or SPA24.

To stop the alarm display blinking, press the ALARM button to change the counter display to the alarm counter and then press the RESET button.

Alarm Recall Display

Check the alarm input information on the ALARM RECALL screen.

NOTICE

M E N U

CLOCK ADJUST SETUP DISPLAY MODE PROGRAM ALARM RECALL TIME DATE SEARCH

END=[DISPLAY]

 

 

 

 

 

 

ALARM RECALL

 

 

AL1

8/19/97TUE 20:35:09

 

AL2

8/ 7/97THU 21:35:16

 

AL3

7/25/97FRI 0:14:12

 

AL4

7/12/97SAT 19:14:12

 

AL5

6/20/97FRI 23:14:10

 

AL6

4/ 1/97TUE 21:07:13

 

AL7 --/--/----- --:--:--

 

1ST

4/ 1/97TUE 21:07:13

 

 

MENU=[DISPLAY]

 

 

 

 

At 1ST, the first (oldest) alarm input information is displayed.

At AL1, the latest alarm input information is displayed.

When more than seven items are input, the old information is erased and the new information is stored in the memory.

To erase the alarm recall contents, press the ALARM button to change the counter display to alarm counter and press the

29 RESET button.

Page 30
Image 30
Toshiba kV-9168A instruction manual Alarm Recording, Operation at Alarm Input, Event Recording, Alarm Recall Display