11.8.42.7 SMART Write Log Sector

COMMAND CODE

1 0 1 1 0 0 0 0

REGISTER

 

REGISTER SETTING

NORMAL COMPLETION

DR

DRIVE No.

no change

CY

 

C24Fh

no change

HD

 

 

no change

SN

Log Sector Address

no change

SC

Number of sectors to write

00h

FT

 

D6h

no change

This command writes an indicated number of 512 byte data sectors to the indicated log.