7. POWER REQUIREMENTS

7.1 Supply Voltage

Allowable voltage

5V + 5%

Allowable noise/ripple

100 mV p-p or less

7.2 Power Consumption

 

Average (note 3)

 

MK1032GAX

Start

4.5W Peak,Maximum

Seek (note 4)

2.4W Typical

Read / Write(note 5)

2.0W Typical

Active idle (note 1)

0.85W Typical

Low power idle (note 6)

0.65W Typical

Stand- by (note 2)

0.18W Typical

Sleep

0.1W Typical

(note 1) Motor is rotating at normal speed but none of Read, Write or Seek is executed.

(note 2) Motor is not rotating and heads are unloaded on the ramp.

(note 3) Under normal condition ( 25oC, 101.3 kPa ( 1,013 mb ) ) and 5V + 0%.

(note 4) The seek average current is specified based on three operations per 100 ms.

(note 5) The read/write current is specified based on three operations of 63 sector read/write per 100 ms.

(note 6) Motor is rotating at normal speed but heads are unloaded on the ramp.

7.3 Energy Consumption Efficiency

Energy consumption efficiency

Average(W/GB)

Classification

Power consumption at Low power idle / Capacity

 

 

MK1032GAX

0.0055

E

Energy consumption efficiency is calculated in accordance with the law regarding efficiency of energy consumption

:Energy saving law,1979 law number 49.

Calculation of Energy consumption is dividing consumed energy by the capacity.

The consumed energy and capacity shall be measured and specified by the Energy saving low.

Toshiba Corporation Digital Media Network Company

Page 16 of 159

© 2004, Copyright TOSHIBA Corporation All Rights Reserved