11.

HOST INTERFACE

 

 

 

Related Standards

 

 

 

 

 

Information technology - AT Attachment Interface with Extensions (ATA-2)

 

 

 

X3T10.279-199x

 

 

 

Information technology - AT Attachment-3 Interface (ATA-3)

 

 

 

X3T10/2008D Revision 6

October 26, 1995

 

 

Information technology - AT Attachment with Packet Interface Extension (ATA -4)

 

 

 

T13/1153D Revision 17

October 30, 1997

 

 

Information technology - AT Attachment with Packet Interface-5 (ATA-5)

 

 

 

T13/1321D Revision 3

February 29, 2000

 

 

Information technology - AT Attachment with Packet Interface-6 (ATA-6)

 

 

 

T13/1410D Revision 3b

February 26, 2002

11.1 Cabling

 

 

 

11.1.1

Interface Connector

 

 

 

 

 

 

 

 

 

 

Drive side

 

Yamaichi GAP050K11617 or equivalent

 

 

connector

 

 

 

 

 

Recommended

for board

straight type

: Berg 86455-044 86456-044

 

 

host side

 

 

or equivalent

 

 

connector

for cable

Berg 89361-044

or equivalent

 

 

 

11.1.2 Cable

The following table shows preferable twisted pair type of cable .

Standard diameter

0.32 mm ( 28 AWG )

Characteristics impedance

100- 132

Toshiba Corporation Digital Media Network Company

Page 27 of 159

© 2004, Copyright TOSHIBA Corporation All Rights Reserved