DIASSEMBLY

4)Attach new lamp

(1)Place the lamp housing to the guide rail and insert the lamp. Check if the power supply connector is securely inserted.

(2)Lock the lamp housing rotating Lock lever.

guide rail

lock lever

lamp unit

5)Attach lamp door.

6)Turn ON the power switch, connect PC with software, Cube commander, or remote control , then

enter to the ADJUST mode SPECIAL mode F STD thus the lamp timer is reset.