11. PROGRAMMING PROCEDURES

11.14 LON SYSTEM

11.14 LON SYSTEM

Menu Group:

2

Item No.:

4

The SL-9000 scales which consist of a master, satellites, and a backup master are connected each other by the LON cable to transmit data such as PLU, ING., NUTRI, etc.

ID# 1 is reserved for the master terminal.

ID# 2 is reserved for the backup master terminal or satellite terminal. ID# 3 to 32 are for satellite terminals.

Setting numbers other than the above results in an error.

 

 

m

<MENU>

4

CHANGE

Group 2

PLU

 

ID #

ENTER

 

 

IN-LINE OFF-LINE

 

 

 

ID#: 1

Set the number of

ENTER

DLL?

Yes

n

 

scales in the system.

 

 

 

 

 

 

 

 

No

 

p

 

 

 

 

 

 

 

PROG.

<MENU>

 

 

 

 

 

 

Group 2

 

 

 

 

 

ESC.

Main

 

 

 

 

 

<MENU>

 

 

 

 

 

 

 

 

 

 

m

NOTES: 1. Before starting the above procedure, press the key and enter IN-LINE mode.

2.When installing the backup master terminal, set the master scale’s initial status of #9-1 to 1.

3.Set ID # to all scales connected by LON cable.

4.When the display power is turned on, a satellite terminal is ready to receive data from the master terminal.

5.After setting the ID #, turn the power switch OFF and ON again.