14. OPERATING PROCEDURES

14.6 TARE/SAVE FUNCTION PROCEDURES

14.6 TARE/SAVE FUNCTION PROCEDURES

Menu: REG., M.DOWN, or REWRAP

Mode: WEIGH or FIX (Tare % function is available in WEIGH mode only.)

There are two kinds of tare subtraction procedures, one is “Direct tare”, the other is “Preset tare”. The SAVE key is used to save the tare, unit price, and PLU data after taking a commodity from the platter.

 

0.200 lb

2

0

0

Tare %

 

Place a container on

 

 

 

 

 

 

1

0

0

the platter.

 

 

 

(Ex. 0.200 lb)

 

 

T

 

 

 

 

 

 

 

 

 

Press:

T

 

 

Press:

%

 

 

 

 

 

 

 

 

 

 

Place a container on

 

 

 

 

 

 

the platter

 

 

Enter the PLU #.

1

0

0

 

 

 

Tare %

 

 

 

 

 

Press:

 

PLU

 

 

 

 

 

 

 

 

 

 

%

 

 

 

 

The PLU data and tare

SAVE

 

 

 

 

 

 

are saved.

 

1

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove the commodity

 

 

 

 

 

%

together with the container.

 

Place a commodity on

 

 

 

 

 

 

 

the platter. (Ex. 1.000 lb)

 

 

 

 

 

 

 

 

 

 

 

 

 

Press:

C

 

 

 

 

 

 

CA type

 

US type

 

 

 

:AUTO

 

 

 

 

 

 

MANUAL: PRT

 

 

 

 

PLU

 

0

Press:

*

The label is issued.

 

 

Press:

 

 

 

 

 

 

Press:

 

 

 

 

 

 

T

Press:

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLU Press:

Remove the commodity

together with the container.

 

 

 

 

 

 

 

 

 

 

NOTES: 1. Tare subtraction is available up to 2.000 lb. for US type, and up to 1.000kg (2.205lb) for the CA/ QR/AU type. When tare subtraction is in operation, however, the scalable range for net weight becomes less by the amount of the tare. (Net weight = Gross weight-Tare)

2.Preset tare must be a multiple of 2 g for CA/QR/AU type (Kg scale) and a multiple of 0.005 lb for US/CA type (Lb scale).

3.The tare % function is available when the Initial Setting #8-7 is set to 1. The speed key #70 will function as the % key (Refer to page 5-3). Set a tare % within the range from 0.0 to 99.9.

4.When a commodity is placed on the platter and the calculated tare exceeds the maximum, a “TARE WEIGH OVER” error will occur.

14-11

Page 75
Image 75
Toshiba SL-9000-LSB owner manual TARE/SAVE Function Procedures, Remove the commodity Together with the container