Trane CG-PRC007-EN 40-60Ton, Performance, Data - 50 HZ, Full Load, Table PD-15- 40Ton - CGAF-C40

Models: CG-PRC007-EN

1 52
Download 52 pages 16.02 Kb
Page 26
Image 26
(40–60Ton)

Performance

(40–60Ton)

Data — 50 HZ

Full Load

 

 

 

 

Table PD-15 — 40Ton — CGAF-C40

 

 

 

 

 

 

 

 

 

 

Entering Condenser Air Temperature (Degree F)

 

 

 

 

 

 

 

 

 

 

 

 

 

85.0

 

 

 

95.0

 

 

 

105.0

 

 

 

115.0

 

 

 

120.0

 

 

 

LWT

Percent Capacity System

 

 

Capacity

System

 

 

Capacity

System

 

 

Capacity

System

 

 

Capacity

System

 

 

 

(Deg F)

Glycol

 

(Tons)

KW

EER

 

(Tons)

KW

EER

(Tons)

KW

EER

 

(Tons)

KW

EER

 

(Tons)

KW

EER

 

 

40

0

28.8

30.0

11.5

27.3

33.5

9.8

25.7

37.6

8.2

24.0

42.2

6.8

23.1

44.6

6.2

 

 

42

0

29.8

30.2

11.8

28.3

33.8

10.0

26.7

37.9

8.4

25.0

42.5

7.0

24.1

45.0

6.4

 

 

44

0

30.9

30.5

12.2

29.3

34.1

10.3

27.7

38.2

8.7

25.9

42.8

7.3

25.0

45.3

6.6

 

 

45

0

31.5

30.6

12.3

29.9

34.3

10.5

28.2

38.4

8.8

26.4

43.0

7.4

25.4

45.5

6.7

 

 

46

0

32.0

30.8

12.5

30.4

34.4

10.6

28.7

38.5

8.9

26.9

43.2

7.5

25.9

45.7

6.8

 

 

48

0

33.1

31.1

12.8

31.5

34.7

10.9

29.7

38.9

9.2

27.8

43.5

7.7

26.9

46.1

7.0

 

 

50

0

34.3

31.3

13.1

32.6

35.0

11.2

30.8

39.2

9.4

28.8

43.9

7.9

27.8

46.4

7.2

 

 

Table PD-16 — 50Ton — CGAF-C50

 

 

 

 

 

 

 

 

 

 

Entering Condenser Air Temperature (Degree F)

 

 

 

 

 

 

 

 

 

 

 

 

 

85.0

 

 

 

95.0

 

 

 

105.0

 

 

 

115.0

 

 

 

120.0

 

 

 

LWT

Percent CapacitySystem

 

 

Capacity

System

 

 

Capacity

System

 

 

Capacity

System

 

 

Capacity

System

 

 

 

(Deg F) Glycol

(Tons)

KW

EER

 

(Tons)

KW

EER

(Tons)

KW

EER

 

(Tons)

KW

EER

 

(Tons)

KW

EER

 

 

40

0

36.0

37.2

11.6

34.2

41.3

9.9

 

32.3

45.9

8.4

30.2

51.0

7.1

29.1

53.8

6.5

 

 

42

0

37.3

37.5

11.9

35.5

41.6

10.2

 

33.5

46.2

8.7

31.4

51.4

7.3

30.2

54.2

6.7

 

 

44

0

38.7

37.8

12.3

36.8

41.9

10.5

 

34.8

46.6

9.0

32.6

51.8

7.5

31.4

54.6

6.9

 

 

45

0

39.4

38.0

12.4

37.5

42.1

10.7

 

35.4

46.8

9.1

33.2

52.0

7.7

32.0

54.8

7.0

 

 

46

0

40.1

38.2

12.6

38.1

42.3

10.8

 

36.0

47.0

9.2

33.8

52.2

7.8

32.6

55.0

7.1

 

 

48

0

41.5

38.5

12.9

39.5

42.7

11.1

 

37.3

47.4

9.5

35.0

52.6

8.0

33.8

55.4

7.3

 

 

50

0

42.9

38.8

13.3

40.9

43.0

11.4

 

38.7

47.7

9.7

36.3

53.0

8.2

35.1

55.9

7.5

 

 

Table PD-17— 60Ton — CGAF-C60

 

 

 

 

 

 

 

 

 

Entering Condenser Air Temperature (Degree F)

 

 

 

 

 

 

 

 

 

 

 

85.0

 

 

 

95.0

 

 

 

105.0

 

 

 

115.0

 

 

 

120.0

 

 

LWT

Percent Capacity

System

 

 

Capacity

System

 

 

Capacity

System

 

 

Capacity

System

 

 

Capacity

System

 

 

(Deg F)

Glycol

 

(Tons)

KW

EER

 

(Tons)

KW

EER

(Tons)

KW

EER

 

(Tons)

KW

EER

 

(Tons)

KW

EER

40

0

46.6

48.3

11.6

44.1

53.7

9.9

 

41.5

59.8

8.3

38.8

66.6

7.0

37.3

70.3

6.4

 

42

0

48.3

48.7

11.9

45.8

54.2

10.1

 

43.1

60.3

8.6

40.2

67.2

7.2

38.7

70.9

6.6

 

44

0

50.0

49.2

12.2

47.5

54.7

10.4

 

44.7

60.9

8.8

41.8

67.8

7.4

40.2

71.5

6.8

 

45

0

50.9

49.4

12.4

48.3

55.0

10.5

 

45.5

61.2

8.9

42.5

68.1

7.5

41.0

71.8

6.8

 

46

0

51.8

49.7

12.5

49.2

55.2

10.7

 

46.3

61.5

9.0

43.3

68.4

7.6

41.7

72.1

6.9

 

48

0

53.6

50.2

12.8

50.9

55.8

10.9

 

48.0

62.1

9.3

44.9

69.0

7.8

43.2

72.8

7.1

 

50

0

55.4

50.7

13.1

52.6

56.3

11.2

 

49.6

62.7

9.5

46.4

69.7

8.0

44.8

73.4

7.3

 

Notes:

1.Data based on 0.0001 fouling factor at sea level.

2.Interpolation between points is permissible.

3.Extrapolation beyond points is not permissible.

4.EER - Energy Efficiency Ratio (Btu/watt-hour). Power inputs include compressors, condenser fans and control power.

5.Ratings based on evaporator drop of 10°F.

6.Rated in accordance with ARI Standard 550/590-98

7.Minimum recommended ethylene glycol percentage used for leaving water temperatures below 40°.

8.Data obtained assuming 400 Volt Supply.

9.Use the following equation to calculate COP values at other than ARI conditions, COP = EER x .2928.

26

CG-PRC007-EN

Page 26
Image 26
Trane CG-PRC007-EN manual 40-60Ton, Performance, Data - 50 HZ, Full Load, Table PD-15- 40Ton - CGAF-C40