Trane PKGP-PRC001-EN manual Rigorous Testing, Features and Benefits, Sloped Drain Pans, VariTrac

Models: PKGP-PRC001-EN

1 52
Download 52 pages 53.39 Kb
Page 7
Image 7
Sloped Drain Pans

Features and Benefits

Reference or Comparative Enthalpy Measures and communicates humidity while maximizing comfort control.

Sloped Drain Pans

Standard on every unit.

Standardized Components Components are placed in the same location on allVoyager units. Familiarize yourself with oneVoyager and you are familiar with every Voyager.

Due to standardized components throughout theVoyager line, contractors/ owners can stock fewer parts.

Supply and/or Return Air Smoke Detector

With this option installed, if smoke is detected, all unit operation will be shut down. Reset will be manual at the unit. Return Air Smoke Detectors require minimum allowable airflow when used with certain models.

Tool-less Hail Guards Tool-less, hail protection quality coil guards shall be either

factory or field-installed for condenser coil protection.This option protects the condenser coil from vandalism and/or hail damage.

VariTrac

WhenTrane’s changeover VAV System for light commercial applications is coupled withVoyager, it provides the latest in technological advances for comfort management systems and can allow thermostat control in every zone served by VariTrac.

Ventilation Override Accessory

With the Ventilation Override Accessory installed, the unit can be set to transition to up to 3 different pre-programmed sequences for Smoke Purge, Pressurization, and Exhaust.The transition occurs when a binary input on the RTOM is closed (shorted).This would typically be a hard wired relay output from a smoke detector or fire control panel.The ventilation override kit is available as a field installed accessory.

Zone Sensors

Available in programmable, automatic and manual styles.

Rigorous Testing

The fan and idler arm assembly designs have been tested to over 300,000 cycles each. Our combined cycle testing is now over 7,000,000 cycles.

All of Voyager’s designs were rigorously rain tested at the factory to ensure water integrity.

Actual shipping tests were performed to determine packaging requirements. Units were test shipped around the country to determine the best packaging. Factory shake and drop tests were used as part of the package design process to help assure that the unit arrives at the job site in top condition.

Rigging tests include lifting a unit into the air and letting it drop one foot, assuring that the lifting lugs and rails hold up under stress.

We perform a 100% coil leak test at the factory.The evaporator and condenser coils are leak tested at 200 psig and pressure tested to 450 psig.

All parts are inspected at the point of final assembly. Sub-standard parts are identified and rejected immediately.

Every unit receives a 100% unit run test before leaving the production line to make sure it lives up to rigorousTrane requirements.

Voyager units incorporate either a one piece top or theTrane-Tite-Top (T3). Each part of the top (either two or three pieces) overlaps in such a way that water cannot leak into the unit.These overlapped edges are gasketed and sealed to ensure superior water integrity.

VariTrac™

Trane Communication Interface (TCI) Available factory or field installed.This module when applied with the ReliaTel™ easily interfaces withTrane’s Integrated ComfortTM System.

PKGP-PRC001-EN

7

Page 7
Image 7
Trane PKGP-PRC001-EN Rigorous Testing, Features and Benefits, Sloped Drain Pans, Supply and/or Return Air Smoke Detector