Trane PKGP-PRC001-EN General, Data12½Ton, CoolingPerformance1, HeatingPerformance1, Compressor

Models: PKGP-PRC001-EN

1 52
Download 52 pages 53.39 Kb
Page 12
Image 12
General

General

Data(12½Ton)

Table GD-1 — General Data

 

12½TonDownflowandHorizontalUnits

 

WCD150B3, B4, BW

WCH150B3, B4, BW

 

 

 

CoolingPerformance1

 

 

Gross Cooling Capacity

152,00

152,000

EER2

9.5

9.5

Nominal CFM / ARI Rated CFM

4,400 / 4,400

4,400 / 4,400

ARI Net Cooling Capacity

144,000

144,000

IntegratedPartLoadValue3

9.9

9.9

System Power KW

15.16

15.16

 

 

 

HeatingPerformance1

 

 

HighTemp.BtuhRating

135,000

132,000

SystemPowerKW/COP

12.76/3.10

12.48/3.10

LowTemp.BtuhRating

78,000

72,000

SystemPowerKW/COP

10.88/2.1

10.55/2.0

HSPF(Btu/Watts-hr)

 

 

 

Compressor

 

 

No./Type

2/Scroll

2/Scroll

 

 

 

ARISoundRating(BELS)4

9.2

9.2

 

 

 

Outdoor Coil —Type

Hi-Performance

Hi-Performance

Tube Size (in.) OD

.375

.375

Face Area (sq ft)

23.96

23.96

Rows/FPI

2/16

2/16

Refrigerant Control

ExpansionValve

ExpansionValve

 

 

 

Indoor Coil — Type

Hi-Performance

Hi-Performance

Tube Size (in.)

.375

.375

Face Area (sq ft)

15.83

17.50

Rows/FPI

2/15

2/15

Refrigerant Control

CapillaryTube

CapillaryTube

Drain Connection No./Size (in.)

1/1.00 NPT

1/1.00 NPT

 

 

 

Outdoor Fan —Type

Propeller

Propeller

No. Used/Diameter (in.)

2/26

2/26

Drive Type/No. Speeds

Direct/1

Direct/1

CFM

10,800

10,800

No.Motors/HP

2/.50

2/.50

MotorRPM

1,110

1,110

 

 

 

Indoor Fan — Type

FCCentrifugal

FCCentrifugal

No. Used

1

1

Diameter x Width (in.)

15 x 15

15 x 15

Drive Type/No. Speeds

Belt/1

Belt/1

No.Motors

1

1

MotorHP(Standard/Oversized)

3.0/5.0

3.0/5.0

MotorRPM(Standard/Oversized)

1,740/3,450

1,740/3,450

Motor Frame Size (Standard/Oversized)

145T/145T

145T/145T

 

 

 

Filters—TypeFurnished6

Throwaway

Throwaway

(No.) Size Recommended (in.)

(2) 20 x 20 x 2

(2) 20 x 20 x 2

 

(4) 20 x 25 x 2

(4) 20 x 25 x 2

 

 

 

RefrigerantCharge(LbsofR-22)5

11.1/11.4 Circuit

11.5/11.8 Circuit

Notes:

1.Cooling Performance and Heating Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Certified in accordance with the Unitary Large Equipment certification program, which is based on ARI Standard 340/360-93.

2.EER is rated at ARI conditions and in accordance with ASHRAE test procedures.

3.Integrated Part Load Value is based in accordance with ARI Standard 210/240 or 340. Units are rated at 80°F entering dry bulb, and 67°F entering wet bulb at ARI rated cfm.

4.Sound Rating shown is tested in accordance with ARI Standard 270 or 370.

5.Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.

6.Optional 2 inch pleated filter also available.

*Indicates both downflow and horizontal units.

12

PKGP-PRC001-EN

Page 12
Image 12
Trane PKGP-PRC001-EN manual General, Data12½Ton, CoolingPerformance1, HeatingPerformance1, Compressor, ARISoundRatingBELS4