Test Mode - Testing Oven Parts

Test Mode - Testing Oven Parts

From screen 2 of the Info mode, press the L1 soft key to access TEST MODE. When prompted, enter the password 9 4 2 8 and press the Enter key.

From TEST MODE, the oven’s components can be tested independently, or a comprehensive/ selective self-test can be run. Unless otherwise specified, idle airflow is set to 10% and the stirrer motor is turned on.

Top Blower

Press the L2 soft key to increase top blower speed in 10% increments.

NOTE: While the top blower is being tested, the bottom blower remains at 10% idle airflow.

Bottom Blower

Press the L3 soft key to increase bottom blower speed in 10% increments.

NOTE: While bottom blower is being tested, the top blower remains at 10% idle airflow.

Heaters

Press the L4 soft key to turn heaters on/off.

NOTE: When the heaters are not being tested, make sure they are turned off; otherwise, the oven will overheat.

Magnetron Test

Press and hold the L5 soft key to turn on the magnetrons. To turn off the magnetrons, simply let go of the L5 soft key.

Stirrer

Press the R1 soft key to turn the stirrer on/off.

L1

TEST MODE

R1

 

 

 

FAULT LOG

 

 

 

 

STIRRER ON

 

L2

TOP BLOWER 10%

 

 

 

 

DIAGNOSTICS OFF

R2

L3

BOTTOM BLOWER 20%

MANUFACTURING MODE

R3

 

 

L4

HEATERS ON

 

 

 

 

SELF TEST

R4

 

 

 

 

 

 

L5

MAG OFF

 

 

 

 

 

R5

P S M t

H

 

B

T

W

Figure 14: Test Mode

15

Test Mode - Status Indicators

Figure 14. The status indicators are located at the bottom of the TEST MODE screen, and consist of:

-P = Primary switch (backlit = open)

-S = Secondary switch (backlit = open)

-M = Monitor switch (backlit = open)

-t = Magnetron thermostat (backlit = open)

-H = Heaters (backlit = on)

-B = Bottom blower (backlit = on)

-T = Top blower (backlit = on)

-W = Microwave (backlit = on)

In Figure 14:

-All three door switches are engaged (closed).

-The heaters are on.

-Both blower motors are on.

-Microwave is not being used.

Test Mode - Fault Log

Press the L1 soft key to access the fault log.

This fault log is identical to the one accessible from screen 1 of the INFO MODE (page 13), except on this screen, pressing the 0 key clears all faults.

Test Mode - Turning On/Off

Diagnostic Mode

Press the R2 soft key to place the oven in

DIAGNOSTIC MODE. When in DIAGNOSTIC MODE,

the oven displays additional cooking parameters during a cook cycle, including:

-Event currently being cooked

-Time left per event

-% wave, % top air, % bottom air

-Status indicators

-Group and recipe name

-CC temperature

-CC set point

For normal oven operation, ensure DIAGNOSTIC MODE is turned off.