Turbo Chef Technologies i5 Installation Near Open Heat Source, Optional Installation Items

Models: i5

1 85
Download 85 pages 17.59 Kb
Page 15
Image 15
4SPECIFICATIONS AND INSTALLATION

4SPECIFICATIONS AND INSTALLATION

Installation Near Open Heat Source

See Figure 4, page 5.

When placing a TurboChef oven near an open heat source, strictly adhere to the following:

-If the oven is being placed near a grill or stove, a divider must exist between the oven and the open heat source, with a minimum of 6” (152

mm)between the oven and the divider.

-If the oven is being placed near a fryer, a divider must exist between the oven and fryer, with a minimum of 12” (305 mm) between the oven and the divider.

-The height of the divider must be greater than or equal to the height of the oven (24.3” or 618 mm).

-Verify oven location has a minimum 16” (406

mm)clearance on top and minimum 2” (51

mm)of clearance on each side.

Optional Installation Items

See Figure 5, page 5.

TurboChef Oven Cart

-Part Number: NGC-1217-3

-Height: 32” (813 mm)

-Width: 27.8” (706 mm)

-Depth: 26.625” (676 mm)

Oven Restraint Kit

Part Number: TC3-0242

Installation Near Open Heat Source WARNING: The Oven Restraint Kit will not prevent the oven from falling off a countertop if the oven is pulled off or allowed to slide off the edge. Installation instructions are included with the kit.

ChefComm Pro

ChefComm Pro is a PC program for developing and maintaining menus and recipes. To purchase ChefComm Pro and a card reader, contact customer service at 800.90TURBO or

+1 214-379-6000.

Voltage Selection

For North America oven models, the oven will detect 208 or 240 incoming voltage.

The initial voltage selection is typically completed before the oven is used by the customer. However, if incoming voltage for the store is different than the preset voltage, the operator will be required to select either 208 or 240 after pressing the On/Off key to turn on the oven. The correct voltage will be enlarged on the screen, identifying which option to select (see Figure 3 below).

SELECT VOLTAGE:

Optional Installation ItemsVoltage Selection 208 VAC

240 VAC

Figure 3: Selecting Voltage

Page 15
Image 15
Turbo Chef Technologies i5 Installation Near Open Heat Source, Optional Installation Items, Voltage Selection