28 OVEN SYSTEMS

Figure 28: Survey Meter Placement

5.Close the oven door and press the Enter key. The microwave system will turn on.

6.Position the microwave survey meter as shown in Figure 28, above.

7.Measure microwave emission around the door, moving the meter sensor at 0.5 inches/second. As microwave leakage is observed moving the sensor at 0.5 inches/second, note any meter spike areas that come close to 5mW/cm2 for later re-measurement.

8.Replace the water load every 60 seconds until the test is completed, and also after scanning the door.

9.Close the oven door and return the meter probe to any "meter spike" areas and allow the probe to remain in the "spike" area for 17 seconds. Note the highest reading obtained.

NOTE: There may be several places on the door where this procedure needs to be done. If so, start out with a fresh water load each time a new area is measured, or if measurement of an area takes longer than 60 seconds.

10.After each test is complete, open the oven door and dispose of the hot water.

Troubleshooting

The following faults may occur in relation to the oven door:

- F4: Monitor (see page 42)

The following issues may occur in relation to the oven door:

-“Cook Door Open” message when door is closed (see page 45).